When
monitoring screen mesh tightness, KRISTEEL-MEC recommends
checking mesh “tension”, measured in newton per centimeter
(n/cm), rather than testing screen “deflection” in mils per
pound. Tension testing will reveal any difference in tightness
between the two perpendicular mesh wire directions within a
single screen, which the deflection method cannot detect.
Measuring in n/cm also provides a means of determining whether
or not the mesh was taken beyond its recommended “yield point”
during the stretching process. |